90H-V ECM ERV
Silver Series
No. produit : 43916 (top ports)
ECO-FRIENDLY AND ENERGY EFFICIENT!
The 90H-V ECM ERV is an energy recovery ventilator that incorporates extremely high performance motors that are equivalent in power consumption to a compact fluorescent light bulb (13.5 watts each), which enable the 90H-V ECM ERV to significantly lower energy costs without affecting its performance.
Moreover, his core absorbs both heat and moisture from the air streams passing through it (without mixing). In the summer, the heat and humidity of the outdoor fresh air is transferred to the exhaust air stream, meaning your home stays cooler inside. In the winter, the opposite is true. Ideal for small to mid-size homes*, this balanced system offers superior indoor air quality and excess humidity control.
Combined with the state-of-the-art programmable Platinum wall control, the 90H-V ECM ERV surpasses energy-saving standards while providing effective heat and energy recovery and ventilation.
The ERV 90H–V ECM is proudly ENERGY STAR® certified.
*Refer to local building code.
To learn more about wall controls compatible with this unit, please refer to the wall controls specification sheet.
Find a dealer
Find a dealer near you (Contact for product availability)
Recovery type | ERV |
---|---|
Exchange rate (CFM) | 40-140 |
Position of ports | Top |
Port diameter | Oval shaped ports; fit 6” ducts |
Comptability of Wall Controls | Platinum, Deco-Touch |
Filter | Washable filters |
---|---|
Warranty on parts (years) | 5 |
Warranty on core or thermal wheel (years) | 5 |
ENERGY STAR © qualified | Yes |
HVI Certified | Yes |
-
Answer
An air exchanger unit will not create humidity. It is used to exhaust excess humid air and replace it with dry air in winter. A humidifier may still be needed.
-
Answer
In this particular case, you should contact an HVAC professional.
-
Answer
Crawl space has to be vented with a separate unit. The principle is that unconditioned space air cannot be mixed with livable space air.
-
Answer
The municipalities have regulations regarding home ventilation; it is important to verify which regulations your municipality applies. The municipalities are in charge of applying these on their territories.
-
Answer
In summer, the humidity level in the house varies with the outdoor conditions (mainly noticeable in the basement). A dehumidifier or an air conditioning system may still be needed.
-
Answer
The air exchanger is used to exhaust excess humid air in winter. Therefore, it is normal to see fog or ice on windows during cold weather. Many factors may contribute to this problem, such as: windows poor insulation quality, heating temperature, barrier in front of the windows (lack of ventilation near the windows caused by blinds, curtains, etc.), dominant winds, drastic changes in outside temperature, etc.
Do not wait to heat your home, especially in the basement. It will remove moisture that has accumulated during summer.
-
Answer
HRV stands for Heat Recovery Ventilator.
Models include HRV 60H, 100H, 200H, HRV 90H-V ECM, 40H, 40H+, Novo+ 100H and Novo+ 200H.
ERV stands for Energy Recovery Ventilator.
Models include ERV 60H, ERV 90H-V ECM and 40E.
-
Answer
Heat Recovery Ventilator (HRV):
The heat recovery ventilator (HRV) is the proper choice in colder climates where there is excess humidity during the heating season, since it can eliminate it.
The HRV keeps the home supplied with a steady flow of fresh outdoor air. As stale, warm air is expelled, the heat recovery core warms the incoming fresh, colder air before it is distributed throughout the home.
The result is a constant supply of fresh air, no unpleasant drafts and greater home comfort.
Energy Recovery Ventilator (ERV):
The energy recovery ventilator (HRV) is suitable for colder climates, in homes where there is no humidity excess during the heating season, as well as for warmer climates homes with high outdoor humidity.
The ERV recovers heat (like the HRV); however, it also recuperates the energy trapped in humidity, which greatly improves the overall recovery efficiency.
In conditioned homes, when it is more humid outside than inside, the ERV limits the amount of humidity coming into your home.
For homes using a humidifier, whit low humidity level in winter, the ERV limits the amount of humidity expelled from your home.
-
Answer
You can ventilate bathrooms with an HRV or an ERV. You can even add timers such as: 20-minute timers, 20/40/60-minute timers or 60-minute mechanical timers (depending on the unit model chosen).
-
Answer
These models have to be installed in an environment where ambient temperature is always above 10°C or 50°F.
-
Answer
Each unit’s control is designed to work with its own circuit board.
-
Answer
No, because there is not enough difference between inside and outside temperature during summer.
-
Answer
These units can be installed independently or connected to your furnace duct(s).
Depending on the installation, the furnace blower will have to run continuously or not in order to have an adequate air circulation.
For further information, please refer to the installation manual of your unit.
-
Answer
It is strongly recommended to balance the unit for optimum performance by a contractor specialized in heating, ventilation and/or air conditioning (HVAC). An unbalanced unit could cause problems (risk of frost in the unit and ducts).
-
Answer
These models are sold and installed by heating, ventilation and/or air conditioning (H.V.A.C.) contractors.
Please consult our Dealer Locator section to find an authorized installer in your region.